Energy Department
The U.S. Department of Energy ("DOE") proposes several clarifications to the test procedures for general service lamps ("GSLs") located in appendix W, appendix BB and appendix DD. Specifically, DOE proposes to clarify that GSLs must not be tested as colored lamps, GSLs that can operate at multiple correlated color temperatures ("CCTs") be tested at one specific CCT, and that lamps with additional components that do not affect light output must be turned off during testing. The proposed clarifications specify that non-integrated lamps be tested with a fluorescent lamp ballast or external driver selected based on compatibility lists and availability; and provide specifications regarding the starting method, ballast factor, number of lamps and references to the relevant industry standards. This rulemaking is limited in scope and is considering clarifications to the current test procedures that are required for certification of compliance with existing applicable GSL energy conservation standards. Further, this rulemaking does not satisfy the Energy Policy and Conservation Act (EPCA) requirement that, at least once every 7 years, DOE review the test procedures for GSLs. DOE is seeking comment from interested parties on the proposal.
Document Headings Document headings vary by document type but may contain the following: the agency or agencies that issued and signed a document the number of the CFR title and the number of each part the document amends, proposes to amend, or is directly related to the agency docket number / agency internal file number the RIN which identifies each regulatory action listed in the Unified Agenda of Federal Regulatory and Deregulatory Actions See the Document Drafting Handbook for more details. Department of Energy 10 CFR Parts 429 and 430 [EERE-2024-BT-TP-0010] RIN 1904-AF67 AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of proposed rulemaking and announcement of public meeting. SUMMARY: The U.S. Department of Energy (“DOE”) proposes several clarifications to the test procedures for general service lamps (“GSLs”) located in appendix W, appendix BB and appendix DD. Specifically, DOE proposes to clarify that GSLs must not be tested as colored lamps, GSLs that can operate at multiple correlated color temperatures (“CCTs”) be tested at one specific CCT, and that lamps with additional components that do not affect light output must be turned off during testing. The proposed clarifications specify that non-integrated lamps be tested with a fluorescent lamp ballast or external driver selected based on compatibility lists and availability; and provide specifications regarding the starting method, ballast factor, number of lamps and references to the relevant industry standards. This rulemaking is limited in scope and is considering clarifications to the current test procedures that are required for certification of compliance with existing applicable GSL energy conservation standards. Further, this rulemaking does not satisfy the Energy Policy and Conservation Act (EPCA) requirement that, at least once every 7 years, DOE review the test procedures for GSLs. DOE is seeking comment from inter…
Other Federal Register documents from the same docket.
Citation: 89 FR 92855