Energy Department
The U.S. Department of Energy ("DOE") is amending the test procedures for ceiling fans to include a definition for "circulating air" for the purpose of the ceiling fan definition; include ceiling fans greater than 24 feet within the scope of the test procedure; include certain belt-driven ceiling fans within the scope of the test procedure; specify that certain very small-diameter ceiling fans are not required to be tested; maintain applicability of the standby power test procedure to large-diameter ceiling fans; specify instructions for testing ceiling fans with certain accessories or features; clarify test voltage for large-diameter ceiling fans; amend the low speed definition and increase low speed tolerance for stability criteria; permit an alternate set-up to collect air velocity test data and provide greater specificity regarding sensor orientation; amend the blade thickness measurement requirement; update instrument measurement resolution, represented values, rounding instructions, and enforcement provisions; and codify current guidance on calculating several values reported on the EnergyGuide label. DOE is also updating references to an industry test standard to reference the latest version.
Document Headings Document headings vary by document type but may contain the following: the agency or agencies that issued and signed a document the number of the CFR title and the number of each part the document amends, proposes to amend, or is directly related to the agency docket number / agency internal file number the RIN which identifies each regulatory action listed in the Unified Agenda of Federal Regulatory and Deregulatory Actions See the Document Drafting Handbook for more details. Department of Energy 10 CFR Parts 429 and 430 [EERE-2013-BT-TP-0050] RIN 1904-AD88 AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Final rule. SUMMARY: The U.S. Department of Energy (“DOE”) is amending the test procedures for ceiling fans to include a definition for “circulating air” for the purpose of the ceiling fan definition; include ceiling fans greater than 24 feet within the scope of the test procedure; include certain belt-driven ceiling fans within the scope of the test procedure; specify that certain very small-diameter ceiling fans are not required to be tested; maintain applicability of the standby power test procedure to large-diameter ceiling fans; specify instructions for testing ceiling fans with certain accessories or features; clarify test voltage for large-diameter ceiling fans; amend the low speed definition and increase low speed tolerance for stability criteria; permit an alternate set-up to collect air velocity test data and provide greater specificity regarding sensor orientation; amend the blade thickness measurement requirement; update instrument measurement resolution, represented values, rounding instructions, and enforcement provisions; and codify current guidance on calculating several values reported on the EnergyGuide label. DOE is also updating references to an industry test standard to reference the latest version. DATES: The effective date of this rule is September 15, 2022. The…
Other Federal Register documents from the same docket.
Energy Conservation Program: Energy Conservation Standards for Ceiling Fans
Energy Conservation Program: Test Procedure for Ceiling Fans; Correction
Energy Conservation Program: Test Procedure for Ceiling Fans
Energy Conservation Program: Energy Conservation Standards and Test Procedures for Ceiling Fans
Energy Conservation Program: Test Procedure for Ceiling Fans
Citation: 87 FR 50396