Base
H898622002-04-12New YorkClassification

The tariff classification of Environmental Monitoring Sensor and Card from India

U.S. Customs and Border Protection · CROSS Database · 1 HTS code referenced

Summary

The tariff classification of Environmental Monitoring Sensor and Card from India

Ruling Text

NY H89862 April 12, 2002 CLA-2-90:RR:NC:N1:105 H89862 CATEGORY: Classification TARIFF NO.: 9025.80.1000 Ms. Karen A. Sousa American Power Conversion Corporation P.O. Box 278 132 Fairgrounds Roads West Kingston, RI 02892 RE: The tariff classification of Environmental Monitoring Sensor and Card from India Dear Ms. Sousa: In your letter dated March 21, 2002, for American Power Conversion, you requested a tariff classification ruling. The page supplied from the Internet indicates that the AP9612TH, Environmental Monitoring SmartSlot Card, includes a Temperature Probe. From the sample and its user’s manual the Probe measures both temperature, to 2 degree C accuracy, and humidity, to 8 percent accuracy of relative humidity. The probe plugs into a female plug on the face plate of a printed circuit board, about 4 inches square, with dozens of ICs, resistors, capacitors, etc, attached. The faceplate also has inputs for sensors for several other environmental conditions, for example, barometric pressure. However, these inputs are for any simple detectors which present an open or closed circuit, not a continuously variable signal as for the temperature and humidity. The board/faceplate converts the raw data from the sensors and measuring devices into a form directly usable by a computer and/or communication devices and can perform some storage of the data. Your installation card indicates that the AG9612TH “exerts no control.” No detailed information was included about how the temperature and humidity are measured, but it appears that the method is “electrical” per Additional U.S. Note 2 to HTS Chapter 90. The applicable subheading for the AP9612TH will be 9025.80.1000, Harmonized Tariff Schedule of the United States (HTS), which provides for, inter alia, “electrical” hygrometers and thermometers, recording or not, and any combination of these instruments. The rate of duty will be 1.7 percent ad valorem. The sample is being returned to you in a separate mailing. This ruling is being issued under the provisions of Part 177 of the Customs Regulations (19 C.F.R. 177). A copy of the ruling or the control number indicated above should be provided with the entry documents filed at the time this merchandise is imported. If you have any questions regarding the ruling, contact National Import Specialist J. Sheridan at 646-733-3012. Sincerely, Robert B. Swierupski Director, National Commodity Specialist Division