Energy Department
The U.S. Department of Energy (DOE) proposes to amend the Federal test procedures for air-cooled commercial package air conditioners and heat pumps with a rated cooling capacity greater than or equal to 65,000 Btu/h, evaporatively-cooled commercial package air conditioners, and water-cooled commercial package air conditioners to incorporate by reference the latest versions of the applicable industry test standards. Specifically, DOE proposes: to amend the current test procedure for this equipment for measuring the current cooling and heating metrics--integrated energy efficiency ratio (IEER) and coefficient of performance (COP), respectively; and to establish a new test procedure for this equipment that would adopt two new metrics-- integrated ventilation, economizer, and cooling (IVEC) and integrated ventilation and heating efficiency (IVHE). Testing to the IVEC and IVHE metrics would not be required until such time as compliance is required with any amended energy conservation standard based on the new metrics. Additionally, DOE proposes to amend certain provisions of DOE's regulations related to representations and enforcement for the subject equipment. DOE welcomes written comments from the public on any subject within the scope of this document (including topics not raised in this proposal), as well as the submission of data and other relevant information.
Document Headings Document headings vary by document type but may contain the following: the agency or agencies that issued and signed a document the number of the CFR title and the number of each part the document amends, proposes to amend, or is directly related to the agency docket number / agency internal file number the RIN which identifies each regulatory action listed in the Unified Agenda of Federal Regulatory and Deregulatory Actions See the Document Drafting Handbook for more details. Department of Energy 10 CFR Parts 429 and 431 [EERE-2023-BT-TP-0014] RIN 1904-AD93 ( printed page 56392) AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of proposed rulemaking and request for comment. SUMMARY: The U.S. Department of Energy (DOE) proposes to amend the Federal test procedures for air-cooled commercial package air conditioners and heat pumps with a rated cooling capacity greater than or equal to 65,000 Btu/h, evaporatively-cooled commercial package air conditioners, and water-cooled commercial package air conditioners to incorporate by reference the latest versions of the applicable industry test standards. Specifically, DOE proposes: to amend the current test procedure for this equipment for measuring the current cooling and heating metrics—integrated energy efficiency ratio (IEER) and coefficient of performance (COP), respectively; and to establish a new test procedure for this equipment that would adopt two new metrics—integrated ventilation, economizer, and cooling (IVEC) and integrated ventilation and heating efficiency (IVHE). Testing to the IVEC and IVHE metrics would not be required until such time as compliance is required with any amended energy conservation standard based on the new metrics. Additionally, DOE proposes to amend certain provisions of DOE's regulations related to representations and enforcement for the subject equipment. DOE welcomes written comments from the public on any subjec…
Other Federal Register documents from the same docket.
Citation: 88 FR 56392