Nuclear Regulatory Commission
The U.S. Nuclear Regulatory Commission (NRC) is amending its spent fuel storage regulations by revising the Holtec International HI- STORM Flood/Wind Multipurpose Canister Storage System listing within the "List of approved spent fuel storage casks" to include Amendment No. 5 to Certificate of Compliance No. 1032. Amendment No. 5 revises the certificate of compliance to: Add new heat load patterns and revise the minimum required cooling time for two multipurpose canisters MPC-89 and MPC-37; add new fuel types to the approved contents; allow an exception to a code to permit use of certain duplex stainless steels; use an analysis model to revise the calculation for evaluating effective fuel conductivities; add the use of the damaged fuel isolator; add two versions of the standard variable weight transfer cask; add the option of using cyclic vacuum drying; and make changes to the final safety analysis report to add new types of fuel assemblies, add a definition to it and to the certificate of compliance, and add the required shielding evaluation to Section 5.4.8. In addition, Amendment No. 5 makes several clarifications and minor changes. These changes are discussed in more detail in the "Discussion of Changes" section of this direct final rule.
Document Headings Document headings vary by document type but may contain the following: the agency or agencies that issued and signed a document the number of the CFR title and the number of each part the document amends, proposes to amend, or is directly related to the agency docket number / agency internal file number the RIN which identifies each regulatory action listed in the Unified Agenda of Federal Regulatory and Deregulatory Actions See the Document Drafting Handbook for more details. Nuclear Regulatory Commission 10 CFR Part 72 [NRC-2020-0050] RIN 3150-AK47 AGENCY: Nuclear Regulatory Commission. ACTION: Direct final rule. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is amending its spent fuel storage regulations by revising the Holtec International HI-STORM Flood/Wind Multipurpose Canister Storage System listing within the “List of approved spent fuel storage casks” to include Amendment No. 5 to Certificate of Compliance No. 1032. Amendment No. 5 revises the certificate of compliance to: Add new heat load patterns and revise the minimum required cooling time for two multipurpose canisters MPC-89 and MPC-37; add new fuel types to the approved contents; allow an exception to a code to permit use of certain duplex stainless steels; use an analysis model to revise the calculation for evaluating effective fuel conductivities; add the use of the damaged fuel isolator; add two versions of the standard variable weight transfer cask; add the option of using cyclic vacuum drying; and make changes to the final safety analysis report to add new types of fuel assemblies, add a definition to it and to the certificate of compliance, and add the required shielding evaluation to Section 5.4.8. In addition, Amendment No. 5 makes several clarifications and minor changes. These changes are discussed in more detail in the “Discussion of Changes” section of this direct final rule. DATES: This direct final rule is effective July 27, 2020, unless…
Other Federal Register documents from the same docket.
List of Approved Spent Fuel Storage Casks: Holtec International HI-STORM Flood/Wind Multipurpose Canister Storage System, Certificate of Compliance No. 1032, Amendment No. 5
List of Approved Spent Fuel Storage Casks: Holtec International HI-STORM Flood/Wind Multipurpose Canister Storage System, Certificate of Compliance No. 1032, Amendment No. 5
Citation: 85 FR 28479